No support in 9.10(1) and later for the ASA FirePOWER module on the ASA 5506-X series and the ASA 5512-X-The ASA 5506-X seriesĪnd 5512-X no longer support the ASA FirePOWER module in 9.10(1) and later due to memory constraints.
To upgrade, see the instructions in the ASA configuration guide.Ĭaution: The ROMMON upgrade for 1.0.5 takes twice as long as previous Version for the ISA 3000 (May 15, 2019) we highly recommend that you Upgrade ROMMON for the ISA 3000 to Version 1.0.5-There is a new ROMMON Or it fails, contact Cisco technical support do not power cycle or If the upgrade is not complete within 30 minutes Do not power cycle theĭevice during the upgrade. ROMMON versions, approximately 15 minutes. To upgrade, see the instructions in the ASA configuration guide.Ĭaution: The ROMMON upgrade for 1.1.15 takes twice as long as previous Upgrade ROMMON for ASA 5506-X, 5508-X, and 5516-X to Version 1.1.15-There is a new ROMMON version for these ASA models (Mayġ5, 2019) we highly recommend that you upgrade to the latest version. Be sure to set all devices on the clusterĬontrol link to the same MTU, specifically 1600 or higher. Switch), then you will start seeing the effects of this mismatch withĭropped cluster control packets. The MTU on connecting switches (for example, you left the MTU as 1500 on the However, if you set the MTU to 1600 but then failed to match The recommended MTU for theĬluster control link has always been 1600 or greater, and this value isĪppropriate. (CSCvr19755)Ĭluster control link MTU change in 9.13(1)-Starting in 9.13(1), many cluster control packetsĪre larger than they were in previous releases. Upgraded to 9.13 from an earlier release only fresh installations areĪffected, such as a new device or a re-imaged device. This problem does not occur if you originally Version to 9.13, or you need to clear your configuration using the FXOSĮrase configuration command. Platform mode: If you downgrade to 9.12 or earlier, you will not be able toĬonfigure new interfaces or edit existing interfaces in FXOS (note that 9.12Īnd earlier only supports Platform mode). See the ASAv Getting Started Guide for information about the resource allocations (vCPU and memory) supported in version 9.13(1).ĭowngrade issue for the Firepower 2100 in Platform mode from 9.13 to 9.12 or earlier-For aįirepower 2100 with a fresh installation of 9.13 that you converted to If your current ASAv runs with less than 2GB of memory, you cannot upgrade to 9.13(1) from an earlier version. You must upgrade to ASDM 7.13(1.101) or 7.14(1.48) to restore ASDMĪSAv requires 2GB memory in 9.13(1) and later-Beginning with 9.13(1), the minimum memory requirement for the ASAv is 2GB. Note: ASDM 7.13(1) and ASDM 7.14(1) also did not support these models For the ASAĥ515-X and ASA 5585-X FirePOWER module, the last supported version is No support in ASA 9.13(1) and later for the ASA 5512-X, ASA 5515-X, ASAĥ585-X, and the ASASM-ASA 9.12(x) is the last supported version.